Schedule 40 Plastic PVC, CPVC and Other Pipe Sizes & Dimensions

Fluid Flow Table of Contents
Hydraulic and Pneumatic Knowledge

Schedule 40 Plastic PVC, CPVC and Other Pipe Sizes and Dimensions | Schedule 40 Pipe

APPLICATION

CPVC IPS sizes 1/4" through 24", for use at temperatures up to and including 200°F. Pressure rating (130 psi to 1130 psi) varies with schedule, pipe size, and temperature. Rresistant to most acids, bases, salts, aliphatic solutions, oxidants, and halogens.

References: ASTM STANDARD D1784 MATERIAL EQUIVALENTS: Cell Classification 23447 = CPVC Type IV Grade 1 = CPVC 4120

Chart gives dimensional - size data for PVC, CPVC and other Schedule 40 Plastic Pipe.

Nominal Size (in)
Outside Diameter (in)
Schedule 40
Wall Thickness (in)
Weight
PVC
(lb/100 ft)
Weight
CPVC
(lb/ 100 ft)
Max.
Pressure
PSI
1/8
.405
.072
-
-
810
1/4
.540
.093
-
-
780
3/8
.675
.096
-
-
620
1/2
.840
.116
16
17
600
3/4
1.050
.120
21
23
480
1
1.315
.141
32
34
450
1 1/4
1.660
.148
43
46
370
1 1/2
1.900
.154
51
55
330
2
2.375
.163
58
74
280
21/2
2.875
.215
107
118
300
3
3.500
.229
141
154
260
3 1/2
4.000
.240
201
220
240
4
4.500
.251
273
-
220
5
5.563
.273
353
386
190
6
6.625
.297
539
581
180
8
8.625
.341
755
824
160
10
10.75
.387
1001
1089
140
12
12.75
.430
1180
-
130
14"
14.000
.456
1180
-
130
16"
16.000
.512
1543
-
130
18"
18.000
.572
-
-
130
20"
20.000
.601
-
-
120
24"
24.000
.697
-
-
120

Related: